LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2011 >> G550 >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> Electrical, Equipment & Instructions -- Testing & Repair -- G-Class (463) >> Testing & Repair >> Check quiescent current consumption - AR54.10-P-1030P

Check quiescent current consumption - AR54.10-P-1030P

MODEL 203, 209, 463.243/244/245/246/247/248/249/250/254/309/322/323/332/333 

Shows model 463.249 

Fig 1: Identifying Cup Holder And Battery Box Lid
G07742157Courtesy of MERCEDES-BENZ USA
INSPECT Checking     
IMPORTANT Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
NOTES Notes on battery All models AH54.10-P-0001-01A
1.1 DANGER Remove dust filter housing for heating/ventilation IMPORTANT Model 203, 209. AP83.00-P-8381P
1.2 Remove cup holder (A) IMPORTANT Model 463.246/249  
1.3 Remove battery box cover (B)    
2.1 Preparing test with quiescent current retention   AR54.10-P-1030-01P 
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
    COMMERCIALLY AVAILABLE TOOLS Quiescent current retention unit CMP 12.2 *WH58.30-Z-1012-09A 
2.2 Prepare test without quiescent current retention unit COMMERCIALLY AVAILABLE TOOLS Multimeter AR54.10-P-1030-02P 
*WH58.30-Z-1001-09A 
3 Switch off all consumers IMPORTANT Remove transmitter/ignition key.
Switch off stationary heater.
Switch off car phone.
Switch off radio.
Switch off interior protection.
Switch off vanity mirror
Switch off reading light.
Turn rotary light switch to "0" position.
Close doors, the interior illumination must go out automatically after a few seconds.
With Comand: Remove CD-ROM from Comand, switch off Comand.
 
DANGER Risk of injury  to skin and eyes caused by handling hot or glowing objects. Wear safety gloves, protective clothing and safety glasses, if necessary. AS00.00-Z-0002-01A
4 Check whether auxiliary water pump is operating IMPORTANT Carefully touch coolant hose or additional water pump Auxiliary water pump operating: ↓,
Do not commence quiescent current test until pump has switched off.
 
5.1 Remove cover below instrument panel (right) Model 463.243/244/245/246/247/248/249/250/254/309/322/323/332/333.
IMPORTANT Do not disconnect any electrical couplings.
AR68.10-P-1520GM
6 Testing quiescent current   AR54.10-P-1030-03P 
    MPECIAL TOOL Baseline current draw test adapter 1 Fig 2
    MPECIAL TOOL Quiescent current test adapter 2 Fig 3
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
    If specification for total quiescent current is not achieved: ↓
Determine circuit with excessive quiescent current consumption.
AR54.10-P-1030-04P 
    Specification not achieved: ↓
Determine fuse-protected components with increased quiescent current consumption. Specification not achieved: ↓
AR54.10-P-1030-05P 
    Determine non-fuse protected components with increased quiescent current consumption. AR54.10-P-1030-06P 
    To check, re-test quiescent current. AR54.10-P-1030-03P 
7 Render electrical system operational IMPORTANT Only if no quiescent current retention device has been used. See: ↓  
    Perform basic programming. AR00.19-P-0200P
Fig 2: Identifying Quiescent Current Test Adapter 1 (140 589 12 21 00)
G07742150Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Quiescent Current Test Adapter 2 (140 589 13 21 00)
G07742151Courtesy of MERCEDES-BENZ USA
COMMERCIALLY AVAILABLE TOOLS

Number Designation
WH58.30-Z-1001-09A Multimeter
WH58.30-Z-1012-09A Quiescent current retention unit