Deployment of emergency tensioning retractor units when no deployment device is present - AR91.40-P-0611-05A
| Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. Interrupt the current supply when working on these units. Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 414, 463 |
AS91.00-Z-0001-01A | |
| Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing upwards, do not subject to temperatures above 100 °C. When working on these units interrupt the current supply and detach airbag (AB) with emergency tensioning retractor test connector/connector (X11/13) Model 202 up to 30.6.93 |
AS91.00-Z-0001-01B | |
| Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | For model 163, 168, 170, 202, 203, 209, 208, 210, 215, 220, 230, 414, 463, not valid for |
AH91.60-P-0611-02P | |
| Ignition cable for firing airbag and seat belt tensioner units | WF58.50-P-9160-02A | ||
| Notes on disposing of airbag and emergency tensioning retractor units | All models | OS91.00-P-0001-01A |
Use of self-fabricated ignition cable
- Fabricate ignition cable with a length of 10 m with pressure switch.
- Plug the 2-pin plug coupling into the corresponding emergency tensioning retractor unit.
- Connect ignition cable to battery.
- Press both pressure switches at the same time.
Keep a distance of 10 m for safety.