LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2011 >> CL600 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- Cl600 (216.376) >> Testing & Repair >> Remove/install blower regulator - AR83.10-P-1200SX

Remove/install blower regulator - AR83.10-P-1200SX

MODEL 216.3, 221.0/1 

Illustrated on model 221 

Fig 1: Identifying Blower Regulator Remove/Install Components (1 Of 2)
G07542925Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Blower Regulator Remove/Install Components (2 Of 2)
G07542926Courtesy of MERCEDES-BENZ USA
REMOVINGINSTALLING Remove/install     
1 Switch off ignition and withdraw transmitter key or Keyless Go start/stop button from the EIS [EZS] control unit IMPORTANT Keyless Go start/stop button only for vehicles with code (889) Keyless Go.  
2 Remove cover below instrument panel on right   AR68.10-P-1520SX
3 Expose electrical wiring harness (1) on housing (2) of blower motor (A32m1) and detach electrical connector (3)    
4 Remove bolts (4)    
5 Remove housing (2) with blower motor (A32m1) from air conditioner housing    
6 Unscrew bolt (5).    
7 Remove blower regulator (A32n1) from housing (2) and detach electrical connector (6)    
8 Install in the reverse order