Check condition of battery - AR54.10-P-1129RBS (Black Series): Notes
MODEL 230 with CODE (P99) "AMG Black Series" special model
| Removing | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Unhook trunk partition | ||
| 2 | Remove trunk floor | ||
| 3 | Remove stowage box for vehicle tool kit | ||
| Check | |||
| 4 | Perform visual inspection of on-board electrical system battery for external leaks | ||
| Remove/install battery | AR54.10-P-0005RBS | ||
| 5 | Check on-board electrical system battery | AR54.10-P-1129-01A | |
| Cold cranking amps as per EN | *BE54.10-P-1015-01A | ||
| 6 | Reduce increased voltage after charging process | For an-board electrical system battery that is disconnected from the on-board electrical system and with the message "Surface voltage" shown on the display of the Midtronics battery tester. |
AR54.10-P-1129-03A |
| 7 | Charge on-board electrical system battery | With the test code "Charge and check" on the Midtronics battery tester. |
AR54.10-P-1130I |
| Install | |||
| 8 | Install stowage box/tray for vehicle tool kit | ||
| 9 | Insert trunk floor | ||
| 10 | Hook trunk partition into place | ||
TEST AND ADJUSTMENT VALUES FOR BATTERY
| Number | Designation | All models | |||
|---|---|---|---|---|---|
| BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold test current | as per EN | A | 850 |