Activate instrument cluster, function - GF54.30-P-2006GZ

MODEL 164 

Shown on model 164.1 

Fig 1: Activate Instrument Cluster Function - Shown On Model 164.1
G05259015Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

Activation of instrument cluster (A1) 

Because it relies on black-screen technology, the details on the instrument cluster (A1) (e.g. displays, gauges, etc.) are clearly visible only when the instrument cluster (A1) has been activated. If the instrument cluster (A1) is activated, the current contents are shown in the displays and the illumination of the instrument (A1) is switched on as well as the fuel reserve indicator lamp (A1e4) actuated.

The instrument cluster is activated by switching on "circuit 15g" A1. After "circuit 15g" is switched off the instrument cluster (A1) remains active for a further 30 seconds, but can be extended up to 2 minutes in the event of the occurrence of active warnings. The instrument cluster is activated with "circuit 15g OFF" A1 under the following conditions:

IMPORTANT If one of the stated conditions occurs while the instrument cluster (A1) is already active, then the instrument cluster (A1) remains activated for a further 30 seconds from this point in time.

Networking 

The status of the left front door rotary tumbler microswitch (M14/6s1) is read in by the rear SAM control unit (N10/8) and placed as a CAN message on the CAN interior.

The status of the standing lamp (ON/OFF) is placed on the CAN interior by the front SAM control unit (N10).

Display monitoring/warning messages via multifunction display, function GF54.30-P-2012GZ