Remove/install housing for fuse and relay box - AR54.15-P-1259GZA
MODEL 164 with ENGINE 156, 272, 273, 642, 629
Shown on model 164.1 with engine 642
| Remove/install | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| 1 | Disconnect battery ground cable | AR54.10-P-0003GZ | |
| 2 | Detach lock (1) and remove the cover of the fuse and relay box (2) | ||
| 3 | Pull off locking lug (4) | ||
| 4 | Detach fuse and relay box (6) from mounts (arrows) | ||
| 5 | Pull fuse and relay box (6) out of housing for fuse and relay box (7); when doing so, remove cable passage (3, 5) | ||
| 6 | Unscrew nut (8, 9) | ||
| 7.1 | Remove housing for fuse and relay box (7) together with bracket | ||
| 8 | Install in the reverse order | ||
| 9 | Perform basic programming | AR00.19-P-0200GZ |