ABC level adjustment switch, component description - GF32.50-P-4233R
MODEL 230 as of 1.3.06 with CODE (487) Active Body Control (ABC)
Location
The level adjustment switch is a component of the lower control panel control unit (N72).
Task/function
With the level adjustment switch, the driver can choose between normal level (NN), a raised level (EN1) and the highest level (EN2). The level is displayed by two function LEDs in the level adjustment switch.
The instrument cluster (A1) stores the driver request in EEPROM. After restart, the same driver request applies as before ignition "OFF".
Speed-dependent level lowering applies to the raised levels (and normal level).
The current driver request is indicated by two function LEDs as soon as the engine is running.
Evaluation of the button position and actuation of the function LED is not performed directly by the ABC control unit, but by the lower control panel control unit.
The lower control panel control unit places the current button position on Controller Area Network bus class B (interior) (CAN-B).