Display of the TELE AID function status - GF82.95-P-2015RM

MODEL 230.4 as of 1.7.04 with CODE (359) TELE AID emergency call system with CODE (494) USA version 

Fig 1: Identifying Multifunction Display
G05076331
Fig 2: Identifying Multifunction Display
G05076332
Fig 3: Identifying Multifunction Display
G05076333
Fig 4: Identifying Multifunction Display
G05076334
Fig 5: Identifying Multifunction Display
G05076335
Fig 6: Identifying Multifunction Display
G05076336
Fig 7: Identifying Multifunction Display
G05076337
Fig 8: Identifying Multifunction Display
G05076338
Fig 9: Identifying Multifunction Display
G05076339

State displays 

Fig 10: State Displays Chart
G05076340

The state display in the SOS pushbutton switch (S93/3) serves as a function check of the Telematic Alarm Identification on Demand (emergency call system) (TELE AID) system.

Switch-on characteristics 

Every time the TELE AID system is switched on, the state display for the SOS pushbutton switch (S93/3) signals system readiness by illuminating for 4 seconds. If there are no faults, the state display for the SOS pushbutton switch (S93/3) goes out after 4 seconds.

Fault behavior 

A TELE AID system error is present when the state display for the SOS pushbutton switch S93/3 does not go out 5 seconds after being switched on or when it comes on at a later time. In the event of a fault, an error messages is displayed on the left multifunction display (A1p13) and on right multifunction display (A1p15) in the instrument cluster (A1).

Triggering a TELE AID emergency call 

After a TELE AID emergency call has been triggered, the state display for the SOS pushbutton switch (S93/3) flashes with a frequency of one 1 Hz. In addition, a status message appears on the left multifunction display (A1p13) and on the right multifunction display (A1p15) in the instrument cluster (A1).

If a TELE AID emergency call could not be placed, the state display for the SOS pushbutton switch (S93/3) lights up continuously. In addition, an error message appears on the left multifunction display (A1p13) and on the right multifunction display (A1p15) in the instrument cluster (A1). If a voice connection is established, the state display for the SOS pushbutton switch (S93/3) returns to the same state as before the TELE AID emergency call was triggered. In addition, a status message appears on the left multifunction display (A1p13) and on the right multifunction display (A1p15) in the instrument cluster (A1).

IMPORTANT If the TELE AID system is in the diagnosis mode, the state display for the SOS pushbutton switch (S93/3) also starts to flash.

A continuous illumination of the state display for the SOS pushbutton switch (S93/3) may have the following causes:

IMPORTANT The emergency call system control unit (N123/4) can be coded by means of STAR DIAGNOSIS so that even if there is no authorization, the state and error displays for the TELE AID system will not illuminate or be displayed on the left multifunction display (A1p13) and on the right multifunction display (A1p15) in the instrument cluster (A1). The dealer has the deactivation of the state display confirmed by the customer in writing using a preprinted form.

  SOS switch, location/task/design/function   GF82.95-P-4107RM 
  Telediagnosis pushbutton switch(es), location/task   GF82.95-P-4105RM 
  TELE AID control unit, location/task/design/function   GF82.95-P-4100RM