Disposing of shock absorber - OS32.25-P-0121-01GH
| Risk of injury caused by drilling gas-filled assemblies or components (noncombustible gases) | Wear safety glasses and a face mask. | AS00.00-Z-0006-01A |
- Remove protective tube, stop damper and rubber mount in the housing eye of the shock absorber.
- Drill a hole in the shock absorber tube approx. 55 mm (dimension a) away from the top edge of the tube using a 5 mm dia. drill bit (gas escapes).
Shock absorber design as a twin tube damper: Bore outer and inner tube.
- Pump the shock absorber empty by pushing in the piston rod several times.
Collect and dispose of hydraulic fluid which runs out. Observe regulations for the disposal of hydraulic fluid.
- Dispose of shock absorber (scrap).
Observe regulations for the disposal of shock absorber (old parts).