LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2009 >> E350 Base >> Repair and Diagnosis >> Steering >> Power Steering >> Steering -- E350 (211.256) >> Basic Knowledge >> SPS solenoid valve, function - GF46.50-P-5000-01B

SPS solenoid valve, function - GF46.50-P-5000-01B

Model 203.0 as of 01.08.01 

Models 203.2, 203.7 

Models 209, 211, 215, 220, 230 

Fig 1: SPS Solenoid Valve Characteristic Graph
G07283512Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 2: Identifying Position Of SPS Solenoid Valve (Open)
G07283513Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 3: Identifying Position Of SPS Solenoid Valve (Closed)
G07283514Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

SPS solenoid valve (Y10) open 

SPS solenoid valve (Y10) closed 

The electronics for actuation of the SPS solenoid valve (Y10) are integrated in the traction system control module (N47). The SPS solenoid valve (Y10) is actuated in pulses. As the vehicle speed increases, the current flow decreases and the SPS solenoid valve (Y10) gradually opens the control valve according to a characteristic (K) defined in the traction system control module (N47).

This regulates the oil flow and thus the torque to be applied to the steering wheel. When the SPS solenoid valve (Y10) is actuated with the maximum current (v=0 km/h), the control valve is closed. No oil flows and the minimum steering wheel torque is set (situation for parking).