Stationary heater/heater booster control unit, task - GF83.70-P-4002-02T

Task 

The STH control unit (A6n1) regulates the STH heater unit's (A6) heater operation, thus heating the interior as programmed. It also monitors the components involved in the heater operation.

Reading the following sensors: 

Control and voltage supply: 

Discrete inputs 

Discrete outputs 

CAN signals 

The STH control unit is integrated into the Controller Area Network bus class B (interior) (CAN-B) for the purpose of data exchange.

Emergency shutoff 

If the temperature of 125°C is exceeded in the heater unit, then the heater unit is permanently switched off via the thermal fuse.

Heater/ventilation duration 

The heating period can be configured using STAR DIAGNOSIS (basic value = 50 min). The ventilation duration can be shortened relative to the heating duration (25, 50 or 75%).