Convenience automatic air conditioning box design - GF83.40-P-2170-01TT
Structure
The comfort automatic air conditioning housing contains the following components:
- Heating system heat exchanger
- Evaporator
- Blower motor (A32m1) with blower regulator (A32n1)
- Heater booster (R22/3)
- Expansion valve
- Activated charcoal filter
- Air duct flaps
- Fresh and recirculated air flaps
- Blending air flap, left
- Blending air flap, right
- Footwell flap, left
- Footwell flap, right
- Defroster flap, left
- Defroster flap, right
- Air flap center nozzle, left
- Air flap center nozzle, right
- Blending air flap rear left
- Blending air flap rear right
- Positioning motors
- Fresh air and recirculated air flap actuator motor (M2/5)
- Left blend air flap actuator motor (M2/6)
- Right blend air flap actuator motor (M2/7)
- Left footwell flap actuator motor (M2/10)
- Right footwell flap actuator motor (M2/11)
- Left defroster vent flap actuator motor (M2/8)
- Right defroster vent flap actuator motor (M2/9)
- Left center air outlet flap actuator motor (M2/12)
- Right center air outlet flap actuator motor (M2/13)
- Left rear blend air flap actuator motor (M16/30)
- Right rear blend air flap actuator motor (M16/31)
The components are accommodated in a housing and therefore form a unit.