Automatic air conditioning housing design - GF83.40-P-2105-04T
Structure
The automatic air conditioning housing contains the following components:
- Heating system heat exchanger
- Evaporator
- Blower motor (A32m1) with blower regulator (A32n1)
- Heater booster (R22/3)
- Expansion valve
- Air duct flaps
- Fresh and recirculated air flaps
- Blending air flap, left
- Blending air flap, right
- Left and right footwell flaps
- Left and right defroster flaps
- Center outlet flap
- Positioning motors
- Fresh air and recirculated air flap actuator motor (M2/5)
- Left blend air flap actuator motor (M2/6)
- Right blend air flap actuator motor (M2/7)
- left and right footwell flaps actuator motor (M2/15)
- left and right defroster vent flaps actuator motor (M2/16)
- Center outlet flap actuator motor (M2/22)
The components are accommodated in one housing and thus form one unit.