Check quiescent current consumption - AR54.10-P-1030T
MODEL 211.0/2
Shown on model 211.0
| Removing | |||
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| 1 | Remove trunk floor covering from trunk. | ||
| 2.1 | Remove spare tire cover or spare tire well trim panel from trunk | Model 211.0, depending on equipment | |
| 2.2 | Remove cover above battery | Model 211.2 | |
| 3 | Prepare vehicle for testing | Vehicles without Keyless Go: Ignition switched off, ignition key removed. Vehicle with Keyless Go: Engine switched off, transmitter key located outside of the vehicle and outside of transmission range. |
|
| 4.1 | Disconnect trailer recognition unit | With code 550 Trailer hitch |
|
| Measure | |||
| 5 | Set multimeter to highest possible current measurement range | When central locking is actuated, currents of approx. 20 A flow. Multimeter |
|
| 6 | Connect multimeter between ground lead (1) and negative pole of electrical system battery without interruption | ||
| 7 | Read out and erase fault memory | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| STAR DIAGNOSIS diagnosis system | |||
| 8 | Mark vehicle so that it is easily visible | ||
| 9 | Close all doors and engine hood | ||
| 10 | Actuate closing wedge on trunk lid lock with trunk lid open | ||
| 11 | Lock vehicle from outside | ||
| Notes on no-load current consumption | AH54.10-P-0003-01T | ||
| 12 | Measure no-load current | If the readings are between 1.2 and 2.5 A, a control unit is usually responsible for keeping the "Bus" awake. In the event of readings between 80 and 180 mA, a control unit usually does not switch off, thereby resulting in an increased quiescent current consumption. |
|
| 13.1 | Separate the control units from the rear SAM control unit with fuse and relay module (N10/2) one after another. After each measurement, reinsert individual fuse and continue with next | ||
| 13.2 | Remove fuses singly one after another and localize defective control unit | ||
| 14 | Disconnect control units from the CAN voltage distributers | AR54.10-P-1030-08T | |
| Wiring diagram for interior CAN bus (X30/4) | PE00.19-P-2300DA | ||
| Wiring diagram for interior CAN bus (X30/7) | PE00.19-P-2300DB | ||
| Wiring diagram for interior CAN bus (X30/6) | PE00.19-P-2300DC | ||
| 15 | Remove multimeter without interruption, connect ground lead (1) to ground point on battery control unit (N82) | *BA54.10-P-1004-01C | |
| Install | |||
| 16 | Install in the reverse order | ||
| 17 | Read out and erase fault memory | ||
| Connect STAR DIAGNOSIS and read out fault memory | AD00.00-P-2000-04A | ||
| STAR DIAGNOSIS diagnosis system |
BATTERY
| Number | Designation | Model 211 | ||
|---|---|---|---|---|
| BA54.10-P-1004-01C | Nut, ground lead to battery control unit | M8 | Nm | 12 |