LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2009 >> CL65 >> Repair and Diagnosis >> External Pages >> Different car >> Section 160 (Overall Vehicle -- Testing & Repair -- E550 (211.090)) >> Testing & Repair >> Remove contacts from standard power timer coupling - AR00.19-P-0120-10A

Remove contacts from standard power timer coupling - AR00.19-P-0120-10A

WARNING: This page is about a different car, the 2009 Mercedes-Benz E550 and 2008 Mercedes-Benz E550. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying New Passenger Vehicle Wiring Harness Repair Kit (220 589 04 99 00)
G07194459Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 2: Identifying Wiring Harness Repair Kit, Basic (000 589 13 99 00)
G07194460Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 3: Identifying Blade Holder With Clamping Pliers (220 589 01 99 50)
G07194461Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 4: Identifying JPT/SPT Blade (220 589 01 99 61)
G07194462Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig 5: Identifying MCP 2.8/Fl Blade. 2.8/JPT/SPT (000 589 13 99 30)
G07194463Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

Unfasten secondary release on version with tab 

  1. Using a suitable tool, at the line side unlock the lugs (1) on lock tab.
  2. Open the tab.
    Fig 6: Unlocking Lugs On Lock Tab
    G07089560Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

    Unfasten secondary release on version with spring (shown on Junior Power Timer, Standard Power Timer coupling) 

  3. Insert a suitable tool between spring (1) and housing and then press spring (1) out.
    Fig 7: Pressing Spring Out
    G07089561Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

    Unfasten secondary release on version with slide 

  4. Using a suitable tool, push the slide valve out of the last detent in direction shown by arrow.

    NOTES Press carefully with the tool so that the gasket at the slide valve is not damaged.

    Fig 8: Pushing Slide Valve Out Of Last Detent
    G07089562Courtesy of MERCEDES-BENZ OF NORTH AMERICA.

    Unpin female contacts from coupling 

  5. Insert blade holder with SPECIAL TOOL clamping pliers with SPECIAL TOOL JPT/SPT blade or SPECIAL TOOL MCP 2.8/Fl. 2.8/JPT/SPT blade from the front through the openings in contact cavity of coupling (1).

    IMPORTANT This step compresses the spring shackles (2) on the female contact.

  6. A slight tug on the corresponding cable will remove the female contact (1) from the coupling.
    Fig 9: Inserting Blade Holder Through Openings In Contact Cavity Of Coupling
    G07089563Courtesy of MERCEDES-BENZ OF NORTH AMERICA.