Disconnect/connect battery ground line - AR54.10-P-0003SX
MODEL 216.3, 221.0 /1
| Disconnect, connect | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | AH54.10-P-0001-01A | ||
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1.1 | End internal on-board electrical system functions | Model 216.3, 221.0/1 up to 1.6.08 Model 216.3, 221.0/1 without code (809) Model year 2009 |
AR54.10-P-0003-01SX |
| 1.2 | Switch off ignition and withdraw transmitter key or Keyless Go start/stop button from the EIS [EZS] control unit | Model 216.3, 221.0/1 as of 2.6.08 or with code (809) Model year 2009 |
|
| 2.1 | Disconnect ground line from on-board electrical system with two batteries | Model 216, 221 up to 1.6.08 except code (809) Model year 2009 | AR54.10-P-0003-03SX |
| *BA54.10-P-1028-01C | |||
| 2.2 | Disconnect ground line from on-board electrical system with one battery | Model 216, 221 (except 221.095 /195) as of 2.6.08 or with code (809) Model year 2009, Except code (B03) ECO start-stop function except CODE (Z07) Maximum protection | AR54.10-P-0003-02SX |
| Model 216.3, 221.0/1 with code (B03) ECO start/stop function | AR54.10-P-0003-02SXS | ||
| *BA54.10-P-1028-01C | |||
| 3 | Connect in the reverse order. | ||
| 4 | Reset clock | On vehicles without code (527) COMAND APS (with navigation), without code (529) HIGH Class Japan and without code (530) COMAND APS USA (with navigation) |
Battery
| Number | Designation | Model 216 | ||
|---|---|---|---|---|
| BA54.10-P-1028-01C | Bolt/nut, ground line of battery to body | M8 | Nm | 16 |