Draining, evacuating and refilling air conditioning, checking function and checking for leaks - AR83.30-P-1760V
MODEL 171.4 with CODE (580) Automatic air conditioning with CODE (581) Comfort automatic air conditioning
Shown on model 171.442
Fig 1: Identifying Sealing Caps, Filling Equipment Connection And Filling Connection Of High Pressure Line - Shown On Model 171.442
| Draining | |||
| Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | - | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | - | |
| Notes on handling refrigerant R134a | Air conditioning system with refrigerant R134a | - | |
| During all steps, the operating instructions for the filling unit must be followed. | |||
| Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/ rear-end door or sliding roof. | When moving components, ensure that no body parts or limbs are within the operating range of moving parts. | - | |
| 1 | Open engine hood and raise to vertical position | AR88.40-P-1000V | |
| 2 | Remove sealing caps (1) | ||
| 3 | Connect the filling equipment connection (2) to the filling connection of the high pressure line (3) and the filling equipment connection (4) to the filling connection for the low-pressure line (5) | *WE58.40-Z-1002-22A | |
| 4 | Suction off refrigerant | ||
| *WE58.40-Z-1002-22A | |||
| Evacuate | |||
| 5.1 | Replace drier cartridge | ||
| All models except 171.473 | AR83.30-P-6521V | ||
| Model 171.473 | AR83.30-P-6521VT | ||
| 6 | Clean refrigerant and evacuate air conditioning system | *WE58.40-Z-1002-22A | |
| Charging | |||
| 7 | Replace the quantity of compressor oil noted when evacuating the air conditioning system with new compressor oil and route back to the refrigerant circuit | ||
| Refrigerant compressor filling quantity | *BF83.55-P-1001-01A | ||
| AR83.30-P-5253PA | |||
| AR83.30-P-5252P | |||
| AR83.30-P-5252P | |||
| AR83.30-P-5252P | |||
| AR83.30-P-5252P | |||
| AR83.30-P-5252P | |||
| AR83.30-P-5252P | |||
| *WE58.40-Z-1002-22A | |||
| 8 | Fill air conditioning system | *BF83.00-P-1001-01A | |
| *WE58.40-Z-1002-22A | |||
| 9 | Perform pressure test on AC system | *WE58.40-Z-1002-22A | |
| 10 | Connect the filling equipment connection (2) to the filling connection of the high pressure line (3) and the filling equipment connection (4) to the filling connection for the low-pressure line (5) | *WE58.40-Z-1002-22A | |
| 11 | Seal with sealing caps (1) | ||
| Check | |||
| 12 | Inspect air conditioning system for leaks with leak detector | *WE58.40-Z-1002-20A |
AIR CONDITIONING SYSTEM/AUTOMATIC AIR CONDITIONING
| Number | Designation | Model 171 | ||
|---|---|---|---|---|
| BF83.00-P-1001-01A | Capacity air conditioning system/ automatic air conditioning | Refrigerant R12 | g | - |
| Refrigerant R134 a | g | 670 | ||
| - | - | - | ||
REFRIGERANT COMPRESSOR
| Number | Designation | Refrigerant compressor 6 SEU14C in model 171 except 171.473 | Refrigerant compressor 7 SEU17C in model 171.473 | ||
|---|---|---|---|---|---|
| BF83.55-P-1001-01A | Refrigerant compressor filling quantity | Compressor oil | cm3 | 120 | 120 |
| F83.55-P-1002-01A | Additional quantity of oil to be added when system suddenly looses charge (e.g. lead torn off) | Compressor oil | cm3 | 40 | 40 |
| F83.55-P-1003-01A | Additional oil filling capacity when replacing condenser | Compressor oil | cm3 | 20 | 20 |
| F83.55-P-1004-01A | Additional oil filling capacity when replacing evaporator | Compressor oil | cm3 | 40 | 40 |
| F83.55-P-1006-01A | Additional oil filling capacity when replacing suction line | Compressor oil | cm3 | 20 | 20 |
| F83.55-P-1007-01A | Additional oil filling capacity when replacing pressure line | Compressor oil | cm3 | 20 | 20 |
| F83.55-P-1008-01A | Additional oil filling capacity when replacing refrigerant compressor | Compressor oil | cm3 | 20 | 20 |
| F83.55-P-1009-01A | Additional oil filling capacity in case of detectable leakage | Compressor oil | cm3 | 20 | 20 |
WORKSHOP EQUIPMENT
| WE58.40-Z-1002-20A | Air conditioning leak detector |
| WE58.40-Z-1002-22A | Air conditioning service station |