Remove and install expansion valve - AR83.30-P-5520V
MODEL 171.4 with CODE (580) Automatic air conditioning with CODE (581) Convenience automatic air conditioning
| Remove | |||
|---|---|---|---|
| Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | - | |
| Conduct if air conditioning system is damaged or leaking | AH83.30-N-0004-01A | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | - | ||
| Notes on handling refrigerant R134a | AH83.30-N-0003-01A | ||
| 1 | Discharge air conditioning system | AR83.30-P-1760V | |
| 2 | Unscrew nuts (2) | ||
| 3 | Detach low-pressure line (3) and seal off opening in low-pressure line (3) using a suitable cap | ||
| *WH58.30-Z-1002-27A | |||
| 4 | Unscrew nut (4) | ||
| 5 | Detach high-pressure line (5) from expansion valve (1) | ||
| 6 | Seal off openings in high-pressure line (5) and in expansion valve (1) using a suitable cap or a suitable stop plug | ||
| *WH58.30-Z-1002-27A | |||
| 7 | Remove bolts (6). | ||
| 8 | Remove expansion valve (1) | ||
| 9 | Seal connecting pipes (8) using suitable caps | ||
| *WH58.30-Z-1002-27A | |||
| Install | |||
| 10 | Remove caps, replace sealing rings (7) and moisten with compressor oil | ||
| *WH58.30-Z-1002-27A | |||
| 11 | Remove stop plug and position expansion valve (1) | *WH58.30-Z-1002-27A | |
| 12 | Moisten screws (6) with compressor oil and screw in | Screw in screws (6) alternately to prevent the expansion valve (1) from tilting on the connecting pipes (8). |
|
| *BA83.30-P-1002-01D | |||
| Figure | |||
| 13 | Remove cap and replace sealing ring of high-pressure line (5) | ||
| *WH58.30-Z-1002-27A | |||
| 14 | Position high-pressure line (5) | ||
| 15 | Tighten nut (4) | *BA83.30-P-1012-01D | |
| 16 | Remove cap and replace sealing ring of low-pressure line (3) | ||
| *WH58.30-Z-1002-27A | |||
| 17 | Position low-pressure line (3) | ||
| 18 | Tighten nut (2) | *BA83.30-P-1011-01D | |
| 19 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. | AR83.30-P-1760V |
AIR CONDITIONING SYSTEM
| Number | Designation | Model 171 except 171.473 | Model 171.473 | |
|---|---|---|---|---|
| BA83.30-P-1002-01D | Bolt of expansion valve | Nm | 4 | 4 |
| BA83.30-P-1011-01D | Nut for low-pressure line to high-pressure line | Nm | 8 | 8 |
| BA83.30-P-1012-01D | Nut for high-pressure line to expansion valve | Nm | 8 | 8 |
COMMERCIALLY AVAILABLE TOOLS
| Number | Designation | |
|---|---|---|
| WH58.30-Z-1002-27A | Set of plugs for air conditioning system | 140 830 01 27 |