Remove/install interior compartment prefuse box - AR54.15-P-1350GZ
MODEL 164
| Remove/instal | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Remove battery | AR54.10-P-0005GZ | |
| *BA54.10-P-1012-01C | |||
| *BA54.10-P-1024-01C | |||
| 2 | Undo nut (3), remove clamping device | *BA54.10-P-1026-01C | |
| 3 | Detach plug of maxi fuses (4) | ||
| 4 | Unclip battery compartment prefuse box (F33) (arrow A) | ||
| 5 | Release locks (arrows B) using suitable tool, disconnect fuse carrier with fuses (2) from battery compartment prefuse box (F33) | ||
| 6 | Undo nuts (1), detach electrical connections | ||
| *BA54.10-P-1026-01C | |||
| 7 | Remove battery compartment prefuse box (F33) | ||
| 8 | Install in the reverse order | ||
| 9 | Perform basic programming | AR00.19-P-0200GZ |
BATTERY
| Number | Designation | Model 164.1/8 | ||
|---|---|---|---|---|
| BA54.10-P-1012-01C | Nut, battery cable to battery terminal | M6 | Nm | 6 |
| BA54.10-P-1024-01C | Nut, battery retaining plate to frame floor | M8 | Nm | 24 |
| BA54.10-P-1026-01C | Nut for line connection on battery compartment prefuse box | M6 | Nm | 7 |
| M8 | Nm | 21 | ||