Remove/install housing for fuse and relay box - AR54.15-P-1259GZA
MODEL 164 with ENGINE 156, 272, 273, 642, 629
Fig 1: Identifying Housing For Fuse And Relay Box Remove/Install Components - Shown On Model 164.1 With Engine 642
Shown on model 164.1 with engine 642
| Remove/instal | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Disconnect battery ground cable | AR54.10-P-0003GZ | |
| 2 | Detach lock (1) and remove the cover of the fuse and relay box (2) | ||
| 3 | Pull off locking lug (4) | ||
| 4 | Detach fuse and relay box (6) from mounts (arrows) | ||
| 5 | Pull fuse and relay box (6) out of housing for fuse and relay box (7); when doing so, remove cable passage (3, 5) | ||
| 6 | Unscrew nut (8, 9) | ||
| 7.1 | Remove housing for fuse and relay box (7) together with bracket | ||
| 8 | Install in the reverse order | ||
| 9 | Perform basic programming | AR00.19-P-0200GZ |