Self-adjustment of mixture formation, function - GF07.10-P-1029AM

ENGINE 113.990 in MODEL 211, 219 

ENGINE 113.991 in MODEL 215, 220 

ENGINE 113.992 in MODEL 230 up to Model Year 2008 /AEJ 07 

ENGINE 113.993 in MODEL 463 up to 31.5.12 

ENGINE 113.995 in MODEL 230 up to Model Year 2008 /AEJ 07 

Fig 1: Identifying Lambda Performance Map For Self-Adjustment Of Mixture Formation
G07870899Courtesy of MERCEDES-BENZ USA

On vehicles fitted with a closed-loop controlled catalytic converter the lambda control determines the injection time so exactly that a certain fuel-air ratio (λ) is maintained in all operating states.

If faults occur e.g. through:

the ME-SFI [ME] control unit (N3/10) automatically performs a correction of the mixture formation. In this case, the lambda map is shifted within certain limits so that the lambda control is not positioned at the lower or upper control stop.

If the mixture composition constantly drifts out of the middle control range (e.g. 0±10%), the ME-SFI [ME] control unit shifts the lambda map under certain operating conditions sufficiently far until a lambda control factor of approx. 0% (g) is again achieved.

Self-adjustment ensures that the mixture composition in the control mode (e.g. warming-up phase) is neither too rich nor too lean. This also prevents the lambda control from moving up to the control limit at high altitudes.

Example: 

As the result of a lean fuel/air mixture the readout of the lambda control factor changes to 18% (e). Under certain operating conditions the lambda performance map is shifted (thick arrow) by the ME-SFI [ME] control unit.

This shifting of the lambda performance map is the self-adjustment of the mixture formation process to the existing air/fuel mixture.

After this self-adjustment the lambda control factor is again in the central control range (g).

Self-adjustment of the mixture formation can be carried out in the following operating states:

The following can be read out with STAR DIAGNOSIS:

Representation of self-adaptation values with STAR DIAGNOSIS: 

The representation is performed in "ms" and means that the displayed value for determining the injection time is either added to or subtracted from the injection time determined by the performance map.

Example: 

Calculated injection time (performance map): 3.0 ms

Value displayed in STAR DIAGNOSIS: +0.3 (ms)

For determining the injection time (fuel injection quantity) the ME-SFI [ME] control unit uses a calculated value of 3.3 ms (3.0 ms+0.3 ms).

Idle correction value 

The maximum correction value is ±1.0 ms.

Partial load correction value 

The maximum correction value is -0.68 to +1.32 ms.

  O2 sensors, location/task/design/function   GF07.04-P-4103AM 
  ME-SFI [ME] control unit, location/task/design/function   GF07.61-P-5000AM