Prepare test without quiescent current retention unit - AR54.10-P-1030-02GX

Fig 1: Identifying Electrical Connection Kit (220 589 05 99 00)
G07876842Courtesy of MERCEDES-BENZ USA
  1. Slacken nut of negative terminal at battery.

    IMPORTANT Do not detach the negative terminal clamp.

  2. Connect positive (+) terminal of measurement cable (6) MPECIAL TOOL to negative terminal clamp of line (1).
  3. Switch on digital multimeter in the highest measuring range "amp(s) direct current".

    IMPORTANT Digital multimeter

  4. Carefully pull negative terminal clamp on battery upward and, when doing so, connect negative (-) terminal of measurement cable (6) MPECIAL TOOL to negative terminal (3) underneath negative terminal clamp.

    IMPORTANT Do not break the circuit when detaching the negative terminal clip otherwise any existing faults will be erased. Do not fully detach the negative terminal clamp until the negative (-) terminal of the measurement cable (6) MPECIAL TOOL has been securely attached to the negative terminal (3).