Measure absolute angle at rear axle housing - AR41.10-P-0085-03T
Measurement - Angle 4
The vehicle must be on its wheels for the measurement. All four angles should be measured in succession without interruption.
An angle that has already been measured can be measured a second time if required. To do this, with the Measurement menu displayed, press the "STEP" button repeatedly until the display indicates Ready to measure the relevant angle.
- Clean contact surfaces (arrows) at rear axle housing to remove paint and/or gasket residuals and remove uneven material using a suitable tool.
Shown: Model 211 with 187 mm dia. rear axle center assembly
- Position rear axle center assembly adapter (020h) on rear axle housing (magnetic).
- Align rear axle differential adapter (020h) horizontally in transverse direction using spirit level (020i).
- Tighten retaining bolts (020k) for rear axle center assembly adapter (020h).
Shown: model 211 with 187 mm dia. rear axle center assembly
- Mount sensor mount (020c) with the two knurled bolts centrally on the sensor (020a).
- Position sensor bracket (020c) with sensor (020a) on rear axle center assembly adapter (020h) by turning slightly to left/right (magnetic).
The spiral cable (020b) of the sensor (020a) must point in the direction of travel for each measurement. Otherwise the measurement will be inaccurate.
Shown: model 211 with 187 mm dia. rear axle center assembly
Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Shown: model 211 with 210 mm dia. rear axle center assembly (210E)
The meter is ready to take a measurement. The value measured is shown on the display.
- Press "SAVE" button.
The values are saved.
Measured values screen for angle 4, display e.g. 2.68°
A confirmation message appears briefly and then the meter indicates that it is ready to measure the next angle (angle 5). The measurement is completed and stored in memory.
- Remove sensor from rear axle differential.
- Remove rear axle differential adapter.
- Detach sensor mount from sensor.
Confirmation screen