Home >> Mercedes Benz >> 2007 >> SLK55 >> Repair and Diagnosis >> Body & Frame >> Exterior Body Panels >> Body Noises, Noise Insulation - 171 Chassis >> Testing & Repair >> Cavity preservation following repair work - AR97.20-P-1500V

Cavity preservation following repair work - AR97.20-P-1500V

MODEL 171 

Engine hood 

Fig 1: Identifying Engine Hood Sealing Area
G05034284Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Front Cross Member Sealing Area
G05034285Courtesy of MERCEDES-BENZ USA

Front cross member 

Fig 3: Identifying Wheelhouse With Complete Left Front Longitudinal Member Sealing Area
G05034286Courtesy of MERCEDES-BENZ USA

Wheelhouse with complete left front longitudinal member 

Fig 4: Identifying Left Inner A-Pillar Sealing Area
G05034287Courtesy of MERCEDES-BENZ USA

Left inner A-pillar 

Left door 

Fig 5: Identifying Left Door Sealing Area
G05034288Courtesy of MERCEDES-BENZ USA

Left outer side longitudinal member 

Fig 6: Identifying Left Outer Side Longitudinal Member Sealing Area
G05034289Courtesy of MERCEDES-BENZ USA
Fig 7: Identifying Left Rear Wheelhouse Sealing Area
G05034290Courtesy of MERCEDES-BENZ USA

Left rear wheelhouse 

Rear center section 

Fig 8: Identifying Rear Center Section Sealing Area
G05034291Courtesy of MERCEDES-BENZ USA

Trunk lid 

Fig 9: Identifying Trunk Lid Sealing Area
G05034292Courtesy of MERCEDES-BENZ USA
DANGER Risk of explosion  and poisoning caused by solvent vapors and gasses. Risk of injury  to skin and eyes when handling anticorrosion agents. Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. -
NOTES Notes on cavity preservation Model 124, 126, 129, 140, 168, 169, 170, 171, 201, 202, 203, 208, 209, 210, 211, 215, 220, 230, 240, 463, 639, 671, 690.6, 901, 902, 903, 904, 905
Model WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7
-
1 Perform repair preservation. IMPORTANT Apply cavity preservation agent from inside to shaded areas only after performing sealing work and paintwork, however, before assembly work. Perform repair preservation twice in sequence after a drying time of 5 minutes.
IMPORTANT The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. The cavities should be dry.
IMPORTANT Move spraying into cavities as far as possible. Spray while slowly moving in and out.
-
REFER TO MAINTENANCE Processing instructions for cavity preservation agent   -
REFER TO BASIC KNOWLEDGE Cavity protection, general   -
    Cavity preservation gun Sata HRS no. 11072 *WE58.40-Z-1006-08A 
    MB cavity wax preservation, 1 l *BR00.45-Z-1003-05A 
2 Remove cavity preservation agent from drain holes IMPORTANT Processing temperature should not be below 15°C. Additional preservation measures may be required depending on the repair area deviating from the standard cavity preservation illustrated. -
WORKSHOP EQUIPMENT

WE58.40-Z-1006-08A Cavity preservation gun
REPAIR MATERIALS

Number Designation Order number
BR00.45-Z-1003-05A Preservation agent A 000 986 72 70 05