Remove and install drier cartridge - AR83.30-P-6521VT
MODEL 171.473 with CODE (580) Automatic air conditioning with CODE (581) Comfort automatic air conditioning
| Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | - | |
| Conduct if air conditioning system is damaged or leaking | All models | AH83.30-N-0004-01A | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | AH83.30-N-0005-01A | |
| Notes on handling refrigerant R134a | Air conditioning system with refrigerant R134a | AH83.30-N-0003-01A | |
| Risk of death cased by vehicle slipping or toppling off of the lifting platform. | Align vehicle between the columns of the hydraulic hoist and position the four support plates below the hoist support points specified by the vehicle manufacturer. | - | |
| 1 | Raise vehicle. | AR00.60-P-1000V | |
| Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/ rear-end door or sliding roof. | When moving components, ensure that no body parts or limbs are within the operating range of moving parts. | - | |
| 2 | Open engine hood and raise to vertical position | AR88.40-P-1000V | |
| 3 | Discharge air conditioning system | AR83.30-P-1760V | |
| *BF83.00-P-1001-01A | |||
| *WE58.40-Z-1002-22A | |||
| 4 | Unclip front grille (2) from front bumper (1) | ||
| 5 | Unplug electrical connector from outside temperature display temperature sensor (B14) | ||
| 6 | Remove bolt (5). | *BA83.30-P-1016-01D | |
| 7 | Remove mounting plate (4) | ||
| 8 | Unscrew bolts (6) | *BA83.30-P-1015-01D | |
| 9 | Detach dryer cartridge (3) from refrigerant lines to the side and remove | ||
| Fig 3 | |||
| 10 | Install in the reverse order |
AIR CONDITIONING SYSTEM
| Number | Designation | Model 171.473 | |
|---|---|---|---|
| BA83.30-P-1015-01D | Bolt for drier to condenser | Nm | 5 |
| BA83.30-P-1016-01D | Bolt for attachment plate to drier | Nm | 11 |
AIR CONDITIONING SYSTEM/AUTOMATIC AIR CONDITIONING
| Number | Designation | Model 171 | ||
|---|---|---|---|---|
| BF83.00-P-1001-01A | Capacity air conditioning system/ automatic air conditioning | Refrigerant R12 | g | - |
| Refrigerant R134 a | g | 670 | ||
| - | - | - | ||
WORKSHOP EQUIPMENT
| WE58.40-Z-1002-22A | Air conditioning service station |