Remove and install blower motor - AR83.25-P-1200V
MODELS 171.4
| Removing, installing | |||
|---|---|---|---|
| 1 | Remove cover below instrument panel on right | AR68.10-P-1520V | |
| 2 | Move sliding piece (1) and sliding piece (2) in direction of arrow, remove cover (3) downwards and move sliding piece (1) back to locking position | ||
| 3 | Disconnect electrical plug (5) | ||
| 4 | Undo screws (6) and remove blower motor (A32m1) downwards | ||
| 5 | Turn blower motor (A32m1) around, release locking lug (7) on plug (8), slide plug (8) downwards and remove | ||
| 6 | Remove blower motor (A32m1) from footwell | ||
| 7.1 | Undo screws (9) and remove cover frame (10) | When replacing the blower motor (A32m1) | |
| 8.1 | Detach electrical connector (11) and remove blower regulator (A32n1) | When replacing the blower motor (A32m1) | |
| 9 | Install in the reverse order | ||
| 10 | Perform function check |