Home >> Mercedes Benz >> 2007 >> SL65 >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Body Electrical -- Testing & Repair -- 230 Chassis >> Testing & Repair >> Disconnect/connect battery ground line - AR54.10-P-0003RBS (Black Series)

Disconnect/connect battery ground line - AR54.10-P-0003RBS (Black Series)

MODEL 230.4 with CODE (P99) "AMG Black Series" Special model 

Fig 1: Disconnecting/Connecting Battery Ground Line - Black Series
G00542746Courtesy of MERCEDES-BENZ USA
REMOVINGINSTALLING Remove/install    
DANGER Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
1 Switch off the ignition and remove the transmitter key from the EIS control unit    
2 Unhook trunk partition    
3 Remove trunk floor    
4 Remove stowage box/tray for vehicle tool kit    
5 Slacken nut (1) and connect ground lead (2) to on-board electrical system battery (G1) IMPORTANTInstallation:  Ensure that the ground line (2) is seated firmly, otherwise the negative terminal may be damaged.  
TORQUE SPECIFICATION *BA54.10-P-1012-01C 
6 Connect in the reverse order. IMPORTANT All electrical consumers must be switched off.  
BATTERY

Number Designation MODEL 230
*BA54.10-P-1012-01C Nut, battery cable to negative terminal/positive terminal M6 Nm 6