Remove/install interior compartment prefuse box - AR54.15-P-1350RT
MODEL 251
| Remove/install | |||
| Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. |
AS54.10-Z-0001-01A | |
| Notes on battery | All models | AH54.10-P-0001-01A | |
| Notes on AGM battery | AH54.10-P-0002-01A | ||
| 1 | Disconnect ground line, expose battery | ||
| Remove/install battery | AR54.10-P-0005RT | ||
| 2 | Undo nut (3), remove clamping device | ||
| 3 | Detach plug of maxi fuses (4) | ||
| 4 | Unclip battery compartment prefuse box (F33) (arrow A) | ||
| 5 | Unlock locking devices (arrows B) using a suitable tool and detach fuse carrier with fuses (2) from battery compartment prefuse box (F33) | ||
| 6 | Undo nuts (1), detach electrical connections | ||
| 7 | Remove battery compartment prefuse box (F33) | ||
| 8 | Install in the reverse order | ||
| 9 | Perform basic programming | AR00.19-P-0200RT |