LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2007 >> R320 >> Repair and Diagnosis >> Electrical >> Body Electrical >> Electrical System, Equipment & Instructions - 251 Chassis - 1 Of 4 >> Testing & Repair >> Charge battery - AR54.10-P-1130RT

Charge battery - AR54.10-P-1130RT

Model 251 

INSPECT Check     
DANGER Risk of explosion  from explosive gas. Risk of poisoning and caustic burns  from swallowing battery electrolyte. Risk of injury  through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
1 Check condition of battery   AR54.10-P-1129RT 
  Charging     
2 Connect charger to battery NOTES
Do not reverse polarity.
Risk of short circuit!
NOTES
Make sure that the vent hose and stop plug of the battery are installed in the correct position. because escaping battery vapor can damage the vehicle paint.
 
3 Charge battery    
REFER TO SPECIAL TOOLS 000 588 00 81 00 Charger   WS54.00-P-0037B
    IMPORTANT The battery charging period is dependent on the charge level of the discharged battery. The battery must be charged using an approved charger. The battery is sufficiently charged when the displayed charging current shown is < 25A material.   
4 Disconnect battery charger NOTES
Switch off charger beforehand.
Risk of arcing.
 
INSPECT Check     
5 Check battery after charging   AR54.10-P-1129RT