Charge battery - AR54.10-P-1130RT
Model 251
| Check | |||
| Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Check condition of battery | AR54.10-P-1129RT | |
| Charging | |||
| 2 | Connect charger to battery | Do not reverse polarity. Risk of short circuit! Make sure that the vent hose and stop plug of the battery are installed in the correct position. because escaping battery vapor can damage the vehicle paint. |
|
| 3 | Charge battery | ||
| 000 588 00 81 00 Charger | WS54.00-P-0037B | ||
| 4 | Disconnect battery charger | Switch off charger beforehand. Risk of arcing. |
|
| Check | |||