LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2007 >> CL600 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- Cl600 (216.376) >> Testing & Repair >> Correct oil level in air conditioning system in the event of repair or slow refrigerant loss - AR83.30-P-5251PB

Correct oil level in air conditioning system in the event of repair or slow refrigerant loss - AR83.30-P-5251PB

MODEL 204, 207, 212, 216, 218, 221 

  Drain     
DANGER Risk of explosion  caused by welding or soldering work on closed air conditioning system. Risk of poisoning  caused by inhaling overheated refrigerant vapors. Risk of injury  to skin and eyes caused by contact with liquid refrigerant. Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. AS83.00-Z-0001-01A 
NOTES Procedure for a damaged or leaky air conditioning system   AH83.30-N-0004-01A 
NOTES Protect air conditioning circuit and components from moisture when carrying out repair work All models with air conditioning AH83.30-N-0005-01A 
IMPORTANT Notes on handling R134a refrigerant All models with R134a refrigerant AH83.30-N-0003-01A 
1 Connect air conditioning service unit and drain air conditioning system (recycling) Air conditioner service unit
 
 
MEASURING Measure     
2 Determine refrigerant loss IMPORTANT Compare quantity of refrigerant evacuated with specified refrigerant capacity
FLUID SPECIFICATION Capacity of refrigerant
Model 204, 207, 212, 218
*BF83.00-P-1001-01I
    Model 216, 221 *BF83.00-P-1001-01H 
INSPECT Checking     
3 Check air conditioning system for leakage IMPORTANT System drained. In event of leakage, see: ↓ AR83.30-P-1761PS 
    Replace defective component.
IMPORTANTInstallation  : Each time the refrigerant circuit is opened, the desiccant cartridge or fluid reservoir must be replaced, see ↓
Remove/install desiccant cartridge:
 
    Remove/install fluid reservoir
Model 216.3, 221.0/1
AR83.30-P-6520SX 
  Fill     
4 Evacuating, filling air conditioning system IMPORTANT When charging air conditioning system, add new oil to refrigerant circuit in the amount equal to the quantity of oil extracted. Observe additional oil filling quantity after replacing parts, see: ↓
Correct oil level in air conditioning system after replacing parts.
AR83.30-P-5252PB 
    Model 216, 221
FLUID SPECIFICATION Refrigerant filling capacity:
*BF83.55-P-1009-01H 
    Model 216, 221 *BF83.00-P-1001-01H 
INSPECT Checking     
5 Check air conditioning system for leakage System filled AR83.30-P-1761UV 
AIR CONDITIONING SYSTEM/AUTOMATIC AIR CONDITIONING

Number Designation     Model 216 Model 221 without air conditioning in rear (code 582)
BF83.00-P-1001-01H Filling capacity air conditioning system/automatic air conditioning Refrigerant R134a g 1070 1070
    Specifications for Operating Fluids Sheet BB00.40-P-0361-00A BB00.40-P-0361-00A
REFRIGERANT COMPRESSOR

Number Designation     Refrigerant compressor in model 216
BF83.55-P-1009-01H Additional oil filling capacity in case of detectable leakage Compressor oil cm3 20
    Specifications for Operating Fluids Sheet BB00.40-P-0362-00A