LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2007 >> CL600 >> Repair and Diagnosis >> Electrical >> Body Electrical >> Connectors & Wiring -- Cl600 (216.376) >> Testing & Repair >> Remove contacts from E 95 coupling - AR00.19-P-0120-05A

Remove contacts from E 95 coupling - AR00.19-P-0120-05A

Fig 1: Identifying New Passenger Vehicle Wiring Harness Repair Kit (220 589 04 99 00)
G07536851Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Wiring Harness Repair Kit Basic (000 589 13 99 00)
G07536852Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Blade Holder With Clamping Pliers (220 589 01 99 50)
G07536853Courtesy of MERCEDES-BENZ USA
Fig 4: Identifying E 95 Blade (220 589 01 99 55)
G07536854Courtesy of MERCEDES-BENZ USA

Unfasten secondary release on version with "E 95 coupling" tab 

  1. Using a suitable tool, push tab in direction of arrow out of locked position.
    Fig 5: Pushing Tab Out Of Locked Position
    G07536855Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with "E 95 coupling" slide 

  2. Using a suitable tool, move slide in direction of arrow into pre-locking position (1).
    Fig 6: Moving Slide Into Pre-Locking Position
    G07536856Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with "E 95 coupling" securing clip 

  3. Push retainer (1) in direction of arrow out of locked position using a suitable tool.

    NOTES The seal may be damaged if the tool is inserted too.

    Fig 7: Pushing Retainer Out Of Locked Position
    G07536857Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with "E 95 coupling" contact retainer 

  4. Press on tabs of contact retainer between the contact cavities (3, 5 or 4, 6) with suitable tool.
  5. Open contact retainer.
    Fig 8: Pressing Tabs Of Contact Retainer Between Contact Cavities
    G07536858Courtesy of MERCEDES-BENZ USA

    Unpin female contacts from "E 95 coupling" 

  6. Insert blade holder with SPECIAL TOOL clamping pliers and SPECIAL TOOL E 95 blade from front side though openings at contact cavity of coupling (2).

    NOTES Insert tool carefully to prevent damaging webs between contact cavity and openings for release tool.

    IMPORTANT This pushes together the springs at the female contact (1).

    Fig 9: Inserting Blade Holder With 95 Blade From Front Side Though Openings At Contact Cavity Of Coupling
    G07536859Courtesy of MERCEDES-BENZ USA
  7. A slight tug on the corresponding cable will remove the female contact (1) from the coupling (2).