Install and weld in center roof paneling - AR65.10-P-1000-04SC
- Install center roof paneling (1), fit using
spacer blocks and fasten using clamping pliers.
When removing, observe specified dimensions and position of
spacer blocks.
- Center roof paneling (1)
(areas A, B, C and D).
Position resistance spot welds at precise position of resistance spot welds made at factory to ensure minimum required strength for weld joints (areas B and D).
3 MIG braze center roof paneling (1) (areas E, F, G and H).