LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2007 >> CL550 >> Repair and Diagnosis >> Engine Performance >> Tune-Up >> Mixture Formation -- Cl550 -- 216 Chassis >> Basic Knowledge >> ME-SFI overrun fuel shutoff, function - GF07.61-P-4019MIS

ME-SFI overrun fuel shutoff, function - GF07.61-P-4019MIS

ENGINE 272.9 (except 272.974) in MODEL 221.0 /1 (except 221.095 /195) as of model year 2009/AEJ 08 

ENGINE 273.9 in MODEL 216.3, 221.0 /1 as of model year 2009/ AEJ 08 

Function requirements for deceleration fuel shutoff, general points 

Deceleration fuel shutoff, general points 

Deceleration fuel shutoff in deceleration mode of the engine has the following tasks:

The ME-SFI (N3/10) control unit performs a deceleration fuel shutoff according to the following sensors and signals:

Function sequence for deceleration fuel shutoff 

In deceleration mode, the ME-SFI [ME] control unit shuts off the fuel injection valves (Y62) according to coolant temperature, engaged gear and engine speed, if the accelerator pedal is not actuated. The fuel injection valves are switched on again when the accelerator pedal is operated.

The ME-SFI [ME] control unit also adjusts the valve overlap to its minimum value using the LH and RH intake camshaft solenoids (Y49/4, Y49/5) and the LH and RH exhaust camshaft solenoids (Y49/6, Y49/7). This ensures that an optimal conversion rate of the catalytic converters is more rapidly achieved.

After deceleration fuel shutoff, the ME-SFI [ME] control unit enriches the fuel-air mixture by briefly extending the injection time, in order to protect of the catalytic converters from enriched oxygen.

In order to prevent a sudden rise in torque when combustion is restarted after a deceleration fuel shutoff, the ME-SFI [ME] control unit briefly shifts the ignition angles of the ignition coils (T1) towards "retard".

Deceleration fuel shutoff is disabled when exhaust temperatures are too high, since the high oxygen content occurring in the exhaust during a deceleration fuel shutoff could cause increased oxidation of carbon monoxide and hydrocarbon (afterburning). The heat so generated can overheat of the catalytic converters.

REFER TO SYSTEM WIRING DIAGRAMS Electrical function schematic, deceleration fuel shutoff ME Model 216 PE07.61-P-2772-97CAB 
  Component description for ME-SFI [ME] control unit N3/10 Engine 273 GF07.61-P-6000MLS