Check condition of battery - AR54.10-P-1129SX

MODEL 216.3 up to 1.6.08 except CODE (809) Model year 2009 

MODEL 221.0 /1 up to 1.6.08 except CODE (809) Model year 2009 

Starter battery (G1/4), 

shown on model 221 

Fig 1: Checking Condition Of Starter Battery
G07638352Courtesy of MERCEDES-BENZ USA

On-board electrical system battery (G1), shown on model 221 

Fig 2: Checking Condition Of On-Board Electrical System Battery
G07638353Courtesy of MERCEDES-BENZ USA
REMOVING Removing     
DANGER Risk of explosion  caused by oxyhydrogen gas. Risk of poisoning and caustic burns  caused by swallowing battery acid. Risk of injury  caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. AS54.10-Z-0001-01A
NOTES Notes on battery   AH54.10-P-0001-01A
IMPORTANT Notes on AGM battery   AH54.10-P-0002-01A
1 Remove center paneling in trunk Model 216.3, 221.0, 221.1 without code (Z07) Maximum protection
for checking the on-board electrical system battery (G1).
AR68.30-P-4600SX
INSPECT Checking     
2 Visual inspection for external leaks IMPORTANT If leaks are found: Replace starter battery (G1/4) and/or on-board electrical system battery (G1).
Refer to: ↓
 
Remove/install starter battery (G1/4) AR54.10-P-0008SX 
Remove/install on-board electrical system battery (G1) AR54.10-P-0009SX 
3 Check fluid level in starter battery (G1/4), add distilled water if necessary not with AGM battery  
4 Test starter battery (G1/4) and/or on-board electrical system battery (G1)   AR54.10-P-1129-01A 
Cold test current
Midtronics battery tester with test clamps
*BE54.10-P-1002-01A 
5 Reduce increased voltage after charging process using volt-amp(s) tester On starter battery (G1/4) or on-board electrical system battery (G1) that is disconnected from the on-board electrical system and where the message "Surface voltage" appears in the display of the Midtronics battery tester.
Midtronics battery tester
Volt/amp tester
IMPORTANT After reducing increased voltage, retest starter battery (G1/4) and/or on-board electrical system battery (G1).
AR54.10-P-1129-03A 
6 Charge starter battery (G1/4) and/or on-board electrical system battery (G1) With the test code "Charge and check" on the Midtronics battery tester.
IMPORTANT After charging, retest starter battery (G1/4) and/or on-board electrical system battery (G1).
AR54.10-P-1130SX 
INSTALLING Install     
7 Install center paneling in trunk Model 216.3, 221.0, 221.1 without code (Z07) Maximum protection after checking the on-board electrical system battery (G1). AR68.30-P-4600SX
TEST AND ADJUSTMENT VALUES FOR THE BATTERY

Number Designation 35 Ah 60 Ah VRLA 60 AH
BE54.10-P-1002-01A Cold test current as per EN A 520 680 510
TEST AND ADJUSTMENT VALUES FOR THE BATTERY

Number Designation 70 Ah VRLA 90 Ah VRLA 95 Ah VRLA
BE54.10-P-1002-01A Cold test current as per EN A 760 950 850