Variable intake manifold switchover valve, ME-SFI fault code description - AD07.61-P-4000-81A
| Variable intake manifold switchover valve | ||
| 1A | Fault code ( |
P2074 (-) |
| 1B | Engine 112, 113 as of 1/01 | P2074-[1] Short circuit to positive (-) |
| Fault code | P2074-[2] Short circuit to ground(-) | |
| ( |
P2074-[4] Line interruption (-) | |
| 2 | Fault storage | After expiry of test duration and fault |
| Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
No activation | |
| 3 | Checking frequency | Continuous |
| 4 | Checked signal or status | Current/ voltage test at variable intake manifold switchover valve |
| 5 | Fault setting conditions | |
| Limit values | ||
| Short circuit to ground | Voltage lower than 2.5 V | |
| Short circuit to positive | Current higher than 4.2 A | |
| Line interruption | No voltage at variable intake manifold switchover valve Approx. 4 to 8 V at output of ME-SFI control unit under no load. |
|
| 6 | Check prerequisites | Battery voltage between 8 and 17 V |
| 7 | Actuation of the variable intake manifold switchover valve is checked for to detect a cable breakage and short-circuit (to ground or battery voltage). A short circuit to ground and a line interruption will be detected when the output stages are locked, while a short circuit to the battery voltage will be detected when the output stages are conducting. The output stage is immediately no longer activated when a fault arises. |