LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2007 >> C280 Base >> Repair and Diagnosis >> Engine Performance >> Tune-Up >> Mixture Formation -- Self-Diagnostic System -- 203 Chassis - 1 Of 2 >> Self-Diagnostic System >> Fault code description for activated charcoal canister shutoff valve, ME-SFI - AD07.61-P-4000-20A

Fault code description for activated charcoal canister shutoff valve, ME-SFI - AD07.61-P-4000-20A

1 Fault code P0446
2 Fault storage after the end of the test period and faults
  Activation "CHECK ENGINE" malfunction indicator lamp (MIL) USA ONLY after two successive driving cycles with faults
3 Frequency of the test continuous
4 Checked signal or status Voltage and current for activated charcoal canister shutoff valve
5 Fault setting conditions 
Limits
 
  Short circuit to ground Voltage < 4 V
  Short circuit to +12 V Current < 4.2 A
  Line interruption no voltage at the activated charcoal canister shutoff valve
approx. 4 - 8 V at unloaded output of ME-SFI control module
  Test duration approx. 1 s
6 IMPORTANT The activation of the activated charcoal canister shutoff valve is tested for line interruption and short circuit (to ground or battery voltage). Short circuit to ground and line interruption is determined with a blocked output stage, whereas short circuit to battery voltage is determined with a conducting output stage.
In the event of faults, the output stage is immediately no longer activated.