Air conditioning not operating - AF46.10-P-6006A
MODEL 203
MODIFICATION NOTES
| 10.12.01 | Supersedes STIP 83.30-021 dated 07.12.2001 |
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES
| Category | Op. no. | Operation text | Time | Acc. no. | Code |
|---|---|---|---|---|---|
| P | 541011 | QUICK TEST | 004 WU/0.3 h | - | - |
| P | 541035 | RECODE CONTROL UNIT | 002 WU/0.2 h | - | - |
| P | 837969 | REPLACE PRESSURE AND TEMPERATURE SWITCH ON CONDENSER | 004 WU/0.3 h | - | - |
| Damage code | Cause | Remedy | |
|---|---|---|---|
| 83 752 | Cause 1: | Remedy 1: | |
| Air conditioning not coded in electronic ignition switch (EZS). | |||
| 1 Start in menu "Control units", "Body", "EZS", "Control unit adaptations", "Read coding and change if applicable", "All codings", "Automatic air conditioning / Automatic temperature" via STAR Diagnosis. | |||
| 2 Check coding for air conditioning and change if necessary. |
|||
| Cause 2: | Remedy 2: | ||
| Pressure/temperature sensor (B12/2) defective. | 1 Check pressure/temperature sensor. | ||
2 Remove/install/replace pressure/ temperature sensor. |