Repair refrigerant circuit - AR83.30-P-1782A

Check    
Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.  
Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.  
Procedure for a damaged or leaky air conditioning system   AH83.30-N-0004-01A 
Protect air conditioning circuit and components from moisture when carrying out repair work   AH83.30-N-0005-01A 
Protect air conditioning circuit and components from moisture when carrying out repair work    
Protect air conditioning circuit and components from moisture when carrying out repair work    
Protect air conditioning circuit and components from moisture when carrying out repair work    
Notes on handling refrigerant R134a   AH83.30-N-0003-01A 
Replace defective refrigerant circuit components    
Check air conditioning system for leakage   AR83.30-P-1761PP