Blower button, function - GF83.40-P-2100-01I
The blower button (
) switches a control voltage of 0 - 6 V to the blower regulator via the automatic A/C pushbutton control module.
There are seven set manual positions, adjustable by increasing or decreasing with the blower button. This allows control of the blower speed between 0 - 100 %. The automatic blower function can be adjusted by pressing the blower button or arresting one of the two AUTO buttons for the blower control.
| Blower switch position (reading on display) | Blower control voltage (manual) | Blower control voltage (automatic mode) |
|---|---|---|
| 1 segment | min. 1.60 V | 0 V to 1.70 V |
| 2 segment | 1.80 V | 1.70 V to 1.90 V |
| 3 segment | 2.00 V | 1.90 V to 2.15 V |
| 4 segment | 2.30 V | 2.15 V to 2.60 V |
| 5 segment | 2.85 V | 2.60 V to 3.10 V |
| 6 segment | 3.60 V | 3.10 V to 4.55 V |
| 7 segment | max. 6.00 V | 4.55 V to 6.00 V |