Retrofitting pressure reservoir and pneumatic lines - AN91.25-P-0001-06M
Model 220
- Glue self-adhesive felt mats (2) to the pressure expansion reservoir (1) on surface areas as chafe guard as shown in figure.
- Slightly crimp edge with rubber hammer (arrow), so that the pressure expansion reservoir (1) cannot be chafed by the edge of the sheet metal panel.
- Fabricate foam rubber elements (5) according to dimensions a = 60 mm and b = 30 mm and install pressure expansion reservoir (1) with foam rubber elements (5) as shown in figure.
The pressure expansion reservoir (1) should be seated firmly in its position.
- Cut pneumatic line for multi-contour backrest (6) and shrink both ends on the T-connector (3).
Install pneumatic line for the multi-contour backrest (6) on front-most plug location of bottom connector strip b of PSE control module (A37).
- Install fabricated line on T-connector (3) and route through reinforcement panel (arrow) toward rear to pressure expansion reservoir (1).
- Glue self-adhesive felt mat (2) to connection area of pneumatic line (4) on reinforcement plate (arrow).
- Install pneumatic line (4) on pressure expansion reservoir (1) and fasten pneumatic line with cable strap.