LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> S430 Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- Testing & Repair -- 215 & 220 Chassis >> Testing & Repair >> Removing and installing right center vent diverter flap actuator motor - AR83.30-P-2080M

Removing and installing right center vent diverter flap actuator motor - AR83.30-P-2080M

MODEL 215, 220 

Fig 1: Identifying Right Center Vent Diverter Flap Actuator Motor Remove/Install Components
G04851479Courtesy of MERCEDES-BENZ USA
REVISIONS

14.10.98 Synchronization of actuator motors Step 11, newly included  
REMOVINGINSTALLING Removal, installation     
1 Remove A/C housing   AR83.30-P-5200M 
2 Unscrew screws (3)    
3 Disconnect actuator motor connectors (7), unclip wiring harness IMPORTANT Connection and disconnection aid  
4 Unclip clips (4)    
5 Pull off 2 clips (5)    
6 Separate air distribution housing (1) from blower housing (2)    
7 Disconnect actuator motor connector (8) IMPORTANT Connection and disconnection aid  
8 Unscrew screws (6)    
9 Pull off right center vent diverter flap actuator motor (M16/18)    
10 Install in opposite order    
11 Perform synchronization of actuator motors IMPORTANT STAR diagnosis, menu point
Actuation, synchronization of actuator motors