LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> S430 Base >> Repair and Diagnosis >> Accessories & Equipment >> Interior/Exterior Trim >> Doors & Windows - 215 & 220 Chassis >> Basic Knowledge >> Power window desynchronization, function - GF72.29-P-4002S

Power window desynchronization, function - GF72.29-P-4002S

MODEL 215, 220 

The counter value for position measuring  becomes invalid with desychronization  .

Function Desynchronization  is performed when

In all these cases there is no longer any relationship between the position recognition  counter value and the actual window position, making it necessary to synchronize  the window.

IMPORTANT

The function of the power window is reduced in the desychronized state. The one-touch up/down feature  is not possible.

  Position recognition, power windows, function   GF72.29-P-4000S 
  Power window synchronization, function   GF72.29-P-4003S 
  Front driver-side door control module, location/purpose/design/function   GF72.29-P-4105S 
  Front passenger-side door control module, location/purpose/design/function   GF72.29-P-4106S 
  Rear door control module, location/purpose/design/function Model 220 GF72.29-P-4102S 
  Rear control module, location/purpose/design Model 215 GF91.29-P-2111A