LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> G55 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Basic Knowledge -- G-Class (463) - 2 Of 2 >> Basic Knowledge >> Flame monitor, location/purpose - GF83.70-P-4006A

Flame monitor, location/purpose - GF83.70-P-4006A

MODEL 210 with CODE (228) Stationary heater 

MODEL 210 up to 31.8.96 with ENGINE 602.982 with heater booster 

MODEL 463 as of 1.6.94 with CODE (H12) Stationary heater Webasto Tele Thermo Top S 

REFER TO BASIC KNOWLEDGE Location   GF83.70-P-4006-01A 
  Purpose The flame monitor (A6r3) is a low resistance PTC resistor whose resistance changes depending on the flame temperature.
It monitors the formation of the flame and the flame behavior over the entire heating operation.
From its signals the control module recognizes:
  • Flame formation when heater starts up and
  • flame behavior during entire heating operation.