LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> G55 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Basic Knowledge -- G-Class (463) - 1 Of 2 >> Basic Knowledge >> Condenser, component description - GF83.40-P-2188G

Condenser, component description - GF83.40-P-2188G

MODEL 463.306 /336 /346 as of model year 2011 /YoM 10 

MODEL 463.202 /222 /236 /237 as of model year 2009 /YoM 08 

MODEL 463.247 /248 /249 /254 /270 /271 /303 /340 /341 as of model year 2007 

Fig 1: Locating Condenser
G07740600Courtesy of MERCEDES-BENZ USA

Location 

The condenser with integral fluid reservoir is in front of the radiator.

Task 

The condenser ensures that the refrigerant compressed by the refrigerant compressor (A9) changes state from gas to liquid.

The hot refrigerant compressed by the refrigerant compressor flows into the condenser from above. The coiled pipes and lamellae absorb this heat extremely rapidly and give it off into the outside air.

This in turn cools the refrigerant. The refrigerant condenses as it cools down and becomes liquid. The liquefied refrigerant enters the fluid reservoir under pressure and flows through a stainless-steel fabric layer to the filter block. The filter block can absorb a specific amount of water. The filter block's pores are matched exactly to the molecular size of the refrigerant. Thus the refrigerant can flow through the filter block. All other substances are held back and retained. The cleaned refrigerant is delivered to the expansion valve via a pressure line.