LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> G55 >> Repair and Diagnosis >> External Pages >> Different car >> Section 2 (Electrical, Equipment & Instructions -- Testing & Repair -- G-Class (463)) >> Testing & Repair >> Connecting and disconnecting quiescent current retension unit - AR54.10-P-1030-07I

Connecting and disconnecting quiescent current retension unit - AR54.10-P-1030-07I

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2015 Mercedes-Benz G550, 2014 Mercedes-Benz G550, 2013 Mercedes-Benz G550, 2012 Mercedes-Benz G550, and 2011 Mercedes-Benz G550. However, it is still accessible from the selected car via links, so may be relevant.

Shown on model 220 

  1. Switch on quiescent current retention unit (7).

    IMPORTANT Quiescent current retention unit

  2. Connect quiescent current retention unit (7) as follows:
    • Connect positive terminal (8) of quiescent current retention unit to positive cable of battery.
    • Connect negative terminal (9) of the quiescent current retention unit to battery ground (W10).
  3. Disconnect negative terminal at battery and insulate negative terminal with insulation tape.
  4. Disconnect positive terminal clamp from battery (only if battery is to be removed).
Fig 1: Connecting Quiescent Current Retention Unit
G07742156Courtesy of MERCEDES-BENZ USA