Home >> Mercedes Benz >> 2006 >> E500 Base >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Electrical System, Equipment & Instructions - Trouble Diagnosis - 211 Chassis >> Trouble Diagnosis >> Fault message in instrument cluster (IC) "Battery/alternator, stop vehicle" - AF54.21-P-8063A

Fault message in instrument cluster (IC) "Battery/alternator, stop vehicle" - AF54.21-P-8063A

MODEL 211 

MODIFICATION NOTES

2.11.04 Cause updated    
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES

Category Op. no. Operation text Time Acc. no. Code
P 542306 Battery control unit, perform reset 002 WU - -
P 541011 Perform quick test 004 WU - -
Damage code Cause Remedy  
  Under certain conditions (deep battery discharging, jump start), a communication fault may occur between the battery control unit (BSG) and the CAN bus. IMPORTANT If this occurs, do not replace the BSG. The following steps must be performed first:
↓
 
  This causes the "red" error message "Battery/alternator - Visit workshop" to be displayed in the in the instrument cluster (IC)" 1 Switch off ignition.  
    2 Pull plug directly from BSG and leave unplugged for at least 5 min ("circuit 30 reset").  
  The STAR DIAGNOSIS quick test indicates this state with the marker "!". The fault "Fault in CAN communication with control unit BSG" is also current or stored in other control units (instrument cluster, SAM). 3 Perform quick test.
IMPORTANT If the BSG is again detected during the quick test, this does not  indicate a defect in the BSG, but rather the communication problem described above
Following the "circuit 30 reset" in the BSG, the displayed fault "CAN communication with control unit BSG faulty" switches status from current to stored in other control units (e.g. instrument cluster, SAM).
IMPORTANT Do not replace the BSG, since we are dealing here with a protective function that is part of the BSG's current production configuration. The BSG will again be fully operational following the "circuit 30 reset".