Home >> Mercedes Benz >> 2006 >> E500 Base >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Electrical System, Equipment & Instructions - Retrofitting & Conversion - 211 Chassis - 1 Of 2 >> Retrofitting & Conversion >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001 >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001TT >> Installing and connecting sensors - AZ54.65-P-0001-03TT

Installing and connecting sensors - AZ54.65-P-0001-03TT

  1. Clip sensor holder (10) into ram strip (13).
    Fig 1: Identifying Sensor Holder Into Ram Strip
    G04984473
  2. Clip sensors (12) into sensor holder (10) so that the connecting coupling is inside pointing to the left side of the vehicle (arrow).
    Fig 2: Clipping Sensors Into Sensor Holder
    G04984474
  3. Clip ram strip (13) onto bumper and connect bumper wiring harness (1) to sensors (12).

    IMPORTANT The connecting coupling with the grommet must be on the left-hand side of the bumper.

    Fig 3: Identifying Bumper Wiring Harness To Sensors
    G04984475
  4. Hook wiring harness (1) into the holders (arrows) provided on the bumper.
    Fig 4: Locating Wiring Harness Holders
    G04984476