Home >> Mercedes Benz >> 2006 >> E500 Base >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Electrical System, Equipment & Instructions - Retrofitting & Conversion - 211 Chassis - 1 Of 2 >> Retrofitting & Conversion >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001 >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001T >> Routing and connecting wiring harness - AZ54.65-P-0001-06T

Routing and connecting wiring harness - AZ54.65-P-0001-06T

  1. Prepare parking assist wiring harness (25) as shown in the diagram and route in the vehicle.
    Fig 1: Identifying Rear SAM/SRB And Overhead Control Panel / FFS Connector
    G04984490
  2. Connect parking assist wiring harness (25) to plug position 17 (arrow) in rear SAM/SRB (N10/2) in left side of trunk.
  3. Connect parking assist wiring harness (25) to parking assist connector on FFS/rear bumper (X35/28).
    Fig 2: Identifying Parking Assist Wiring Harness
    G04984491
  4. Route parking assist wiring harness (25) through the left-hand cable duct in the rear wall to the overhead control panel/FFS connector (X25/8) and connect warning element wiring harness (22).
  5. Fasten wiring harnesses with cable straps.
    Fig 3: Identifying Control Panel/FFS Connector
    G04984492
  6. Route parking assist wiring harness (25) in left-hand cable duct to the area of the left A-pillar.
  7. Unclip CAN-B voltage distributor connector (X30/7) from cable duct and unlock.
  8. Connect branch-off line from parking assist wiring harness (25) to voltage distributor (X30/7).
  9. Lock voltage distributor and clip into cable duct.
    Fig 4: Identifying CAN-B Voltage Distributor Connector