Charge battery - AR54.10-P-1130T
MODEL 211, 219
Fig 1: Identifying Ground Cable, Screw, Electrical Connector And Battery Control Unit Components - Model 211, 219
Shown on model 211.0 up to 31.5.06
| Check | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Check condition of battery | AR54.10-P-1129TX | |
| Charging | |||
| 2 | Connect charger to battery | Connect the negative terminal of the charger to body ground (2) only (not to the battery negative terminal) so that the battery control unit (N82) (up to 31.5.06) or battery sensor (as of 1.6.06) can detect charging of the battery. |
|
| 3 | Charge battery | Normal charging: Charging current max. 10 % of battery capacity: e.g. max. 10 A charging current for a 100 Ah battery. Rapid charging: Charging current max. 50 % of battery capacity for 30 minutes: e.g. max. 50 A charging current for 100 Ah battery. |
|
| 4 | Disconnect battery charger | ||
| Check | |||
| 5 | Check battery after charging | AR54.10-P-1129TX |