Error message in instrument cluster in red lettering at high outside temperatures and faults codes 9050 and 9051 are stored in the battery control unit - AF54.10-P-8030A
MODEL 211.### ## up to 350386
Operation no. of operation texts or standard texts and flat rates
OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES
| Category | Op. no. | Operation text | Time | Acc. no. | Code |
|---|---|---|---|---|---|
| P | 541011 | Perform quick test | 004 WU | - | - |
| P | 542300 | Replace control unit for on-board electrical system (after testing), MODEL 211.0 | 009 WU | - | - |
| P | 542300 | Replace control unit for on-board electrical system (after testing), MODEL 211.2 | 012 WU | - | - |
| Damage code | Cause | Remedy | |
|---|---|---|---|
| 54 849 73 | Battery control unit (BSG) | 1 Check Q-status and part number of battery control unit (BSG). | |
| The BSG cannot display any voltage or current values in these conditions. | (A 211 540 27 45) and with a white HT stamp on the housing are installed in the series production. | ||
| The following fault messages could be shown in red lettering in the instrument cluster (KI): | |||
|
(A 211 540 27 45) are being installed in the series production. | ||
|
The white stamp on the housing is now omitted. | ||
↓ 2 Remove/install/replace battery control unit (BSG). |
PARTS ORDERING NOTES
| Part no. | Designation | Quantity |
|---|---|---|
| A 211 540 27 45 | Battery control unit | as required |